Kilometer range

Avia 2

Further reach. Finer detail.

Avia 2 LiDAR sensor
€3,109net price / unit

Recommended accessory for Avia 2

Livox connector cable

Livox Connector Cable — 1.5 m

RJ45 data connector, PVC-shielded cable — made for the Avia 2. Other lengths (15 cm – 10 m) available on request.

€79net

Avia 2 is our longest-range LiDAR sensor. Built around a laser operating in the 1535 nm band1 with a microscopic beam spot, it reaches a maximum detection range of up to 1000 m2 and lets you switch between a wide and narrow field of view. A built-in rain and fog noise reduction algorithm delivers stable, dense point clouds even in difficult weather conditions.

Normal: 400 m@5%*
Focus: ≥ 800 m@10%
Detection range2
0.25 × 0.25 mradBeam divergence3
Normal: 80°×80°
Focus: 15°×15°
Field of view
≤ 0.02°@1σAngular precision
5–400 m: ≤4cm@1σ
400–700 m: ≤6cm@1σ
Range precision
approx. 62,500 hrs4MTTF

* equivalent to approx. 600 m at 10% reflectivity

Range

Kilometer-range detection2

Avia 2 uses a 1535 nm laser1 with concentrated energy and a smaller beam spot, driving a step change in range. It detects targets with 5% reflectivity at 400 m (equivalent to approx. 600 m at 10% reflectivity) in Normal mode, and in Focus mode detects targets with 10% reflectivity up to 800 m from the sensor — with a maximum cutoff range of 1000 m. A single device covers extreme distances, significantly lowering deployment cost.

Point cloud visualization of a city skyline in Normal mode
Precision

Narrow beam, greater range3

With a beam divergence of 0.25 × 0.25 mrad, the spot diameter at 100 m is just 2.5 cm. This concentrated energy makes it possible to precisely detect thin objects — power lines, branches or structural elements — from a great distance, while also penetrating dust and raindrops to reduce measurement noise.

Point cloud visualization of a power pylon with a distance annotation
Weather conditions

Rain and fog noise reduction5

Avia 2 uses high-precision sampling to identify the signatures of interference such as raindrops, and effectively filters out abnormal noise during precipitation. This increases point cloud usability, reduces data processing load, and keeps the sensor operating reliably year-round, regardless of weather.

Point cloud visualization of a road scene with active rain noise reduction
Flexibility

Two fields of view for different scenarios

The sensor offers two operating modes: 80°×80° in Normal mode for wider scene coverage, and 15°×15° in Focus mode for greater detection range. Users can flexibly switch between them as needed — without swapping hardware.

Avia 2 Normal mode (400 m, 80°×80°) vs Focus mode (800 m, 15°×15°)
Reliability

Durable design, low maintenance costs4 6

Avia 2 was engineered for high reliability and stability. Its estimated MTTF reaches 62,500 hours, and the unit operates across temperatures from −20°C to 65°C. This durability significantly reduces operating and service costs across multi-year deployments.

−20°C … 65°C Operating temperature range IP66 Full dust and water resistance 62,500 hrs Estimated MTTF

Avia 2 continuing to operate through heavy frost buildup

Scene coverage

Non-repetitive scanning for dense coverage

A scanning method based on a wedge prism guarantees that every scan trajectory is unique. As scan time increases, unscanned areas shrink and scene coverage becomes progressively denser — enabling detection of even small objects at medium and long range.

Non-repetitive scan buildup — Normal mode vs Focus mode, 5 s

Applications7

Diverse deployment scenarios

Kilometer range and a microscopic beam spot mean a single Avia 2 replaces many short-range sensors.

Power & utilities

Power line security

A single Avia 2 covers a stretch of power line up to a kilometer long, significantly reducing deployment costs. Its microscopic beam spot precisely detects thin objects: wires, branches or crane arms. Combined with non-repetitive scanning, it delivers rich point cloud detail, cutting down false alarms.

Rail infrastructure

Track condition monitoring

Enables remote monitoring of track condition over long distances and detection of small obstacles — rocks, branches or slope slides — even in difficult weather. The wide 80°×80° field of view in Normal mode covers embankments on both sides of tunnel entrances as well as the overhead catenary system.

Industry & logistics

Bulk material volume measurement

In dusty, poorly lit environments such as storage yards or silos, the sensor effectively penetrates dust, delivering stable data with a high signal-to-noise ratio. A single device covers extensive material piles, simplifying inventory automation at a lower deployment cost.

Water management

Smart waterways

Thanks to its long range, a single Avia 2 covers extensive bodies of water. Combining non-repetitive scanning with centimeter-level accuracy captures consistent point clouds throughout a vessel's passage. The rain and fog noise reduction algorithm keeps performance stable in variable weather, supporting safe, round-the-clock navigation.

Which model fits?

Avia vs Avia 2

Same lineage, a full generation apart — Avia 2 trades the original 905 nm laser for a 1535 nm design with far greater range. Avia spec data from Livox’s own datasheet, shown here for reference.

Livox Avia 2Avia 2You’re hereLivox AviaAviaPrevious generation
Range (@100 klx)Normal: 400 m @5%
Focus: ≥800 m @10%
190 m @10%
230 m @20%
320 m @80%
False alarm rate (@100 klx)≤ 0.01%< 0.0003%
Range precision5–400 m: ≤ 4 cm @1σ
400–700 m: ≤ 6 cm @1σ
< 2 cm @20 m (80%)
Angular random precision (1σ)≤ 0.02°< 0.05°
Horizontal FOVNormal: 80°
Focus: 15°
70.4°
Vertical FOVNormal: 80°
Focus: 15°
77.2°
Beam divergence—0.28° × 0.03°
Data rateNormal: 350,000 pts/s
Focus: 100,000 pts/s
240,000 pts/s
480,000 (dual echo)
720,000 (triple echo)
Supply voltage9–27 V DC10–15 V DC
PowerRegular: 55 W start / 50 W steady
Low temp: 55 W start / 45 W steady
Rated ≤ 9 W
Startup ≤ 31 W
Dimensions (L×W×H)With fan: 146 × 113 × 139 mm
Without fan: 146 × 113 × 103 mm
91 × 61.2 × 64.8 mm
WeightWith fan: ≤ 1.8 kg
Without fan: ≤ 1.5 kg
498 g (excl. cables)
Operating temperature−20 °C…65 °C−20 °C…65 °C
Time synchronizationGPS (PPS + GPRMC)
PTP (IEEE 1588)
NTP
IEEE 1588-2008 (PTPv2)
PPS
GPS (UTC + PPS)
Data interface100 Mbps Ethernet100 Mbps Ethernet
Laser wavelength & safety class1535 nm · Class 1905 nm · Class 1
Ingress protectionIP66IP67

Avia (1st generation) is shown for reference only — TPI currently distributes Avia 2.

Footnotes

  1. The 1535 nm laser belongs to the broader eye-safe 1550 nm (1.5 μm) band — it delivers the physical properties, Class 1 safety rating and long-range detection capability equivalent to a 1550 nm laser.
  2. In Normal mode, maximum detection potential is 600 m at 10% reflectivity; however, to maintain a stable point rate of 350,000 pts/s, the cutoff range in this mode is set at 400 m. In Focus mode, maximum detection potential at 10% reflectivity reaches 800 m, with a cutoff range of 1000 m in this mode. Values measured under controlled conditions — actual results may vary depending on the environment.
  3. Beam divergence calculated under laboratory conditions using an infrared camera; the spot diameter at 100 m is a theoretical value derived from this divergence.
  4. The 62,500-hour figure is a typical MTTF calculated from accelerated-aging tests at elevated temperature under controlled conditions — it does not represent actual continuous operating time.
  5. The rain and fog noise reduction function is designed primarily for light to moderate precipitation. Reduction effectiveness may vary depending on the intensity of the weather event and ambient conditions.
  6. The operating temperature range was measured under controlled conditions. Actual temperature tolerance during operation depends on ventilation and sun exposure at the installation site.
  7. During installation and operation, avoid pointing strong laser light sources with a wavelength near 1535 nm directly at the sensor, and do not aim it at highly reflective surfaces at close range — this can permanently damage the receiver.
Technical specifications

Full technical data for Avia 2

ModelAvia 2
Laser wavelength1535 nm 1
Laser safety classClass 1 (IEC60825-1:2014) — eye-safe
Detection range (@100 klx) 2Normal: 400 m@5% reflectivity (~600 m@10% eq.) · Focus: ≥ 800 m@10% reflectivity
Max. detection range 2Normal: 400 m · Focus: 1000 m
Field of view (FOV) 3Normal: 80°×80° · Focus: 15°×15°
Blind zone5 m @ 80% reflectivity
Range accuracy and precision 45–400 m: accuracy ≤5 cm, precision ≤4 cm@1σ · 400–700 m: accuracy ≤10 cm, precision ≤6 cm@1σ
Angular precision≤ 0.02°@1σ
Point rateNormal: 350,000 pts/s · Focus: 100,000 pts/s
Point cloud data formatx / y / z / intensity / tag (Cartesian coordinates)
False alarm rate (@100 klx) 5≤ 0.01%
Return modeStrongest return, first return, dual return
IMUBuilt-in, model LX-IMU640
Operating temperature 6−20°C to 65°C
IP ratingIP66
Power consumption 7Room temperature: 55 W start-up / 50 W steady-state · Low temperature: 55 W start-up / 45 W steady-state
Supply voltage9–27 V DC
Data portEthernet 100 Mbps
Data synchronizationGPS (PPS + GPRMC), PTP (IEEE 1588), NTP
DimensionsWith fan: 146×113×139 mm · Without fan: 146×113×103 mm (± 0.5 mm)
WeightWith fan: ≤ 1.8 kg · Without fan: ≤ 1.5 kg
SDK compatibilityLivox SDK2, ROS / ROS2
Documentation

Manuals and product information

Official documentation published by Livox — always the current version, straight from the source.

Avia 2 user manual (PDF) Full installation, wiring and mounting reference
Download PDF
Avia 2 product information (PDF) Key specifications and product overview sheet
Download PDF
Avia 2 3D model (STEP) CAD file for mounting design and integration planning
Download STEP
FAQ

Frequently asked questions

What is Avia 2's peak power draw in low temperatures?

At low ambient temperature (fan off), start-up power reaches 55 W, with steady-state power around 45 W. We recommend sizing the power supply with at least a 20% margin above peak.

How much point cloud integration time is needed to reach maximum range?

To get a stable reading near 1000 m in Focus mode, we recommend integrating data over at least several to a dozen or so seconds of scanning — the exact time depends on target size and reflectivity.

Can I remove the housing and use just the module in an embedded design?

We don't recommend removing the housing — it voids the IP66 rating and the warranty. For OEM projects we offer a dedicated modular version on individual request.

What should I watch for when powering the unit at 9 V?

Near the lower end of the supply range (9 V DC), account for voltage drop along the cable — for runs longer than 5 m we recommend a cable with a cross-section of at least 1 mm².

Does Avia 2 support hot plugging?

Yes. The power/data connector is protected against current surges and supports safe connection and disconnection while powered.

Is the rain and fog noise reduction feature enabled by default?

Yes, it's active out of the box. Sensitivity and operating mode can be adjusted in Livox SDK2 or the device's configuration panel.

How does fan control work?

A built-in thermal system automatically adjusts fan speed based on internal temperature. Below −10°C the fan stays off to reduce power consumption.

What is Avia 2's IP rating?

IP66 — full protection against dust and powerful water jets from any direction.

Where is the built-in IMU located relative to the point cloud?

The center of the built-in IMU coincides with the origin of the point cloud coordinate system (0,0,0) — IMU and LiDAR data are factory-calibrated relative to each other.

Need a quote for a larger deployment?

We'll prepare an offer tailored to the scale of your project and site conditions.